LABCOM group is responsible for the LHD data acquisition and archiving system called the LABCOM System. Here, we provide various kinds of data related support for the LHD staffs and collaborators in data acquisitions and managements, and also in remote participation for the experiment. For more information, click the links for what you'd like to see or do.
Japanese
You are the th visitor since 4 July 2000
: Contents viewable in the Japanese font ONLY.
Contact : LABCOM
Privacy policy
Please be sure to read the above policy before entering and sending personal information from any forms.

Saving multi-purpose data (dbStore)

...Contents viewable in the Japanese font ONLY.

You can register or save individually collected random block (raw) data, random binary sequence data such as sequence data generated after the primary processing of raw data, and experiment parameters.
Process for registering and saving the data is shown below.

Specify the data name Specify the name of data to be saved.
  • The data name is one to be registered on the database and is used when the data is returned in retrieve.
  • Only alphabetic and numeric characters as well as - (hyphen) can be used for the data name. Also, data names are case-sensitive.

Submit the application for dbStore data registration.  

 
Install the Retrieve+dbStore. Please install the latest version.

 
Setup the environment variables. (set up only when they haven't been set up.) Usually, the environment variables are automatically setup when installing the Retrieve+dbStore. However, there are times that the setup program does not start properly. In such cases, please manually set up the environment variables following the procedure given here.
 

Do you use the software (PV-WAVE/IDL) ?

NO→

Application programming interfaces for utilizing dbStore with software other than PV-WAVE/IDL are provided in DLL format. For more details, please select from the start menu → program → LABCOM Retrieve+dbStore, then, refer to the "dbstoreEXE Manual".

 YES↓

   

Install the software.

Install the PV-WAVE or IDL.

When using PV-WAVE
Install PV-WAVE.
An user account with the LHD domain is required to download PV-WAVE. If you haven't registered yet, apply for the user account with LHD domain first. Click here for more information.
When using IDL
Install IDL.
IDL is downloadable from the Analysis Information Group homepage. Follow the direction provided by the group to install.
 

Specify the executable file at the time of software program start-up. 

Set up Retrieve+dbStore to start operating when PV-WAVE or IDL is started.

PV-WAVE
Replace
[folder where the Retrieve is installed (default C:\LABCOM\Retrieve)] \lib\pv-wave\wavestartup with [folder where the PV-WAVE is installed (default C:\VNI)] \wave\bin\wavestartup.
IDL
After starting the program, specify
[folder where the Retrieve is installed (default C:\LABCOM\Retrieve)] \lib\idl\startup_user_idl.pro」 at the "startup file" found in [Preferences..] in the file menu.
 
Save the data. For the method to save the data with PV-WAVE, click here for the detail.